Broseley eVolution 4 Especificações Página 20

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 19
eVo5MS0711 08/07/2011
TroubleShooting
1. Smokecomesoutofthestovewhentheloadingdoorisopened.
Thechimneycavityintowhichthe125mmfluepipehasbeeninstalledmaybelessthan
theminimumrequirement.
Deposits(soot)mayhavebuiltupinthechimneyandberestrictingtheflowofwaste
products.Thisflowrateisknownasthe‘draw’.
2. TheStovedoesnotproducetheexpectedheatintotheroom.
Hasthefluepipebeense aledtothechimneytopreventheatbeingdrawnupthe
chimneytowaste?
Greenorwetwoodisbeingburnt.
Thechimneyhasexcessivedraw(thisisunusual).Seekinstalleradvicewithregard
toinstallingaFlueDraughtStabiliser.
Thestovehasbeenrecessedintotheexistingfireplaceandalotofheatisabsorbed
bethesurroundingfireplacewallsratherthanbeingradiatedintotheroom.Pullthe
stoveforward.
Forthemaximumefficiencyofheattransferenceintotheroomthestoveshouldbe
sitedonthehearthofthefireplaceratherthanrecessed.
3. TheStoveburnstoofast.
Usewholelogsratherthansplitones.
Thewoodbeingusedmaybegenerally
toosmall.
The“airtight”sealbetweenthefibreropeonthe doorsandthecastingmayhavebeen
lost,adjustdoorhandlelocknutstoreinstatethisseal.
Thechimneyhasexcessivedraw(seekinstallersadviceonthispoint).
Thefibreropesealbetweenthedoorand
theglassmaybeleaking.Tightenorreplace.
Theglassisnotsealed,gentlytightenglassretainingclips.Donotovertightenasthiswill
stressorbreaktheglass.
Thefibreropeondoorsandglasshaswornout.Replace.
4. TheCastingsdonot
lineup
Thereareseveralpositionsonthesidecastingstoallowadjustmentifthecastingsdo
notlineupcorrectly.Byusingsmallrotationsadjustthescrewsattachedtothesideto
suitthedesireddistanceneeded.
Ensurethebaseisattachedcorrectlyandorlinesuptothesidecastingsbefore
tighteningfully.
Vista de página 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Comentários a estes Manuais

Sem comentários